User's Manual
Equipment Calibration68P09255A69-3
Aug 2002
1X SC4812ET Lite BTS Optimization/ATP Software Release 2.16.1.x
PRELIMINARY
F-27
Table F-18: HP 437 Power Meter Calibration Procedure
Step Action
6 Press [ZERO].
- Display will show “Zeroing ******.”
- Wait for process to complete.
7 Connect the power sensor to the POWER REF output.
8 Turn on the PWR REF by performing the following:
8a - Press [SHIFT] then [].
8b - Verify that the triangular indicator (below) appears in the display above PWR REF.
9 Perform the following to set the REF CF%:
9a - Press ([SHIFT] then [ZERO]) for CAL.
9b - Enter the sensor’s REF CF% from the sensor’s decal using the arrow keys and press [ENTER].
(The power meter will display ”CAL *****” for a few seconds.)
NOTE
If the REF CAL FACTOR (REF CF) is not shown on the power sensor, assume it to be 100%.
10 Perform the following to set the CAL FAC %:
10a - Press [SHIFT] then [FREQ] for CAL FAC.
10b - On the sensor’s decal, locate an approximate calibration percentage factor (CF%) at 2 GHz.
10c - Enter the sensor’s calibration % (CF%) using the arrow keys and press [ENTER].
-- When complete, the power meter will typically display 0.05 dBm. (Any reading between
0.00 and 0.10 is normal.)
11 To turn off the PWR REF, perform the following:
11a - Press [SHIFT] then [].
11b - Disconnect the power sensor from the POWER REF output.
F