User's Manual

Test Equipment Inter-unit Connection, Testing, and Control68P09255A69-3
Aug 2002
1X SC4812ET Lite BTS Optimization/ATP Software Release 2.16.1.x
PRELIMINARY
F-21
Figure F-14 shows the connections when using an external 10 MHz
Rubidium reference.
Figure F-14: Cable Connections for Test Set with 10 MHz Rubidium Reference
SERIAL I/O
GPIB
CONNECTOR
ADVANTEST R3465
REAR PANEL
FROM 10 MHZ
RUBIDIUM REFERENCE
LOCAL IN
SERIAL I/O
IF OUT
SYN REF IN
10 MHZ OUT
PARALLEL
EXT TRIGGER
10 MHZ REF
GATE IN
GPIB
CDMA CLOCK OUT
AC POWER
AC POWER
R3465/3463
REAR PANEL
R3561L
REAR PANEL
TO T-CONNECTOR
ON FRONT PANEL
(EVEN SEC/SYNC IN)
X
YZ
421 MHZ
TO POWER METER
GPIB CONNECTOR
TO GPIB
INTERFACE BOX
FW00371
R3465 GPIB Clock Set-up
Table F-15 describes the steps to set the clock for the Advantest R3465
equipment.
Table F-15: Advantest R3465 Clock Setup
Step Action
1 Observe the current date and time displayed in upper right of the CRT display.
2 If the date and time are incorrect, perform the following to change them:
2a - Push the Date/Time CRT menu key.
2b - Rotate the vernier knob to select and set.
2c - Push the vernier knob to enter.
2d - Push the SHIFT then PRESET pushbutton (just below the CRT display).
F