User's Manual

BTS Equipment Identification continued
PRELIMINARY
1X SCt4812ET Lite BTS Optimization/ATP
08/01/2001
1-16
Figure 1-1: SC4812ET Lite Logical BTS Span Cabling
BTSSPAN 1
BTSSPAN 101
TO XC
TO XC
(Optional)
BTSSPAN 102
(Optional)
AB A B
Frame 101
(Expansion
Frame)
Frame 1
(Starter
Frame)
SCCP Shelf Card/Module Device ID Numbers
All Ethernet LANaddressable modules in the logical BTS frames at a
single site are also identified with unique Device ID numbers dependent
upon the Frame ID number in which they are located. Refer to Table 1-2,
Table 1-3, and Figure 1-5 for specific SCCP Shelf Device ID numbers.
Table 1-2: SCCP Cage Module Device ID Numbers (Top Shelf)
Frame Module ID Number (Left to Right)
#
Power
(PS1)
Power
(PS2)
AMR
1
GLI2
1
MCC2 BBX2 BBX2R MPC/
EMPC
1
1 1 1 1 2 1 2 3 R1
101 101 101 101 102 101 102 103 R101
Table 1-3: SCCP Cage Module Device ID Numbers (Bottom Shelf)
Frame Module ID Number (Left to Right)
#
HSO/
LFR
CSM
1
CSM
2
CCD
A
CCD
B
AMR
2
GLI2
2
MCC2 BBX2 SW MPC/
EMPC
2
1 1 2 2 2 3 4 4 5 6
101 101 102 102 102 103 104 104 105 106
1