Alarms Testing
68P09255A69-3
Aug 2002
1X SC4812ET Lite BTS Optimization/ATP Software Release 2.16.1.x
PRELIMINARY
3-104
AC Fail Alarm
Table 3-56 gives instructions on testing the AC Fail Alarm.
Table 3-56: AC Fail Alarm
Step Action
1
NOTE
- Back-up batteries must be installed when performing this test.
- To prevent inadvertently shutting down the RF compartment electronics, the batteries should be
charged before performing this test.
Set the ACLC MAIN circuit breaker to OFF.
- The LMF should report an alarm for an AC Fail condition as BTS Relay #21, BTS Relay #23,
BTS Relay #24, and BTS Relay #29 contacts, respectively.
- On the MAP, the MAJOR ALARM (red), MINOR ALARM (amber), and RECTIFIER FAIL
(red) LEDs should light.
- On the rectifiers, the DC and PWR LEDs should light red.
2 Set the ACLC MAIN circuit breaker to ON.
- On the LMF, the AC Fail alarm should clear.
- On the MAP, the MAJOR ALARM, MINOR ALARM, and RECTIFIER FAIL LEDs should
extinguish.
- On the rectifiers, the DC and PWR LEDs should change to green.
Minor Alarm
Table 3-57 gives instructions on performing a test to display a minor
alarm.
Table 3-57: Minor Alarm
Step Action
1 Set the TCP switch on the MAP to OFF. This will generate a minor alarm.
- The LMF should report the minor alarm as BTS Relay #24 contacts.
- The TC DISABLE (red) and MINOR ALARM (amber) LEDs on the MAP should light.
2 Set the TCP switch to ON.
- The alarm condition indications should clear.
Rectifier Alarms
The following series of tests are for single rectifier modules in a multiple
rectifier system. The systems include a three rectifier and a four rectifier
system.
3