User's Manual

RFDS Set-up and Calibration
68P09255A69-3
Aug 2002
1X SC4812ET Lite BTS Optimization/ATP Software Release 2.16.1.x
PRELIMINARY
3-94
Table 3-45: RFDS Parameter Settings
Step Action
8c
- Click OK to close the status report window.
NOTE
If the LMF displays an error message, check the following:
Ensure AMR cable is correctly connected from the BTS to the RFDS.
Verify RFDS has power.
Verify RFDS status LED is green.
Verify entries in RFDS fields of the bts-#.cdf file are correct (refer to step 1).
Status the MGLI and ensure it is communicating (by Ethernet) with the LMF, and is in the proper
state (INS_ACT (bright green)).
RFDS TSU NAM Programming
The Number Assignment Module (NAM) information needs to be
programmed into the TSU before it can receive and process test calls, or
be used for any type of RFDS test. The RFDS TSU NAM must be
programmed with the appropriate system parameters and phone number
during hardware installation. The TSU phone and TSU MSI must be
recorded for each BTS used for OMC-R RFDS software configuration.
NOTE
The user will only need to program the NAM for the initial
installation of the RFDS.
3