User's Manual

Test Set Calibration68P09255A69-3
Aug 2002
1X SC4812ET Lite BTS Optimization/ATP Software Release 2.16.1.x
PRELIMINARY
3-67
Manually Selecting Test Equipment in a Serial Connection Tab
Test equipment can be manually specified before or after the test
equipment is connected. The LMF does not attempt to verify the test
equipment is actually detected when manual selection is specified.
Follow the procedure in Table 3-28 to manually select test equipment.
Table 3-28: Selecting Test Equipment Manually in the Serial Connection Tab
Step Action
1 In the LMF window menu bar, click Tools and select Options... from the pull-down menu.
- The LMF Options window appears.
2 If it is not in the forefront, click on the Serial Connection tab.
3 Select the correct serial port in the COMM Port: pick list (normally COM1).
4 If it is not selected (black dot showing), click on the Manual Specification button.
5 Click on the check box(es) corresponding to the test equipment item(s) to be used.
6
Type the GPIB address in the corresponding GPIB address box (refer to the Setting GPIB Addresses
section of Appendix NO TAG for directions on verifying and/or changing test equipment GPIB
addresses).
Motorola-recommended addresses are:
1 = signal generator
13 = power meter
18 = communications system analyzer
NOTE
When test equipment items are manually selected by the operator, the LMF defaults to using a power
meter for RF power measurements. The LMF will use a communications system analyzer for RF
power measurements only if a power meter is not selected (power meter checkbox not checked).
7 Click on Apply.
- The button will darken until the selection has been recorded.
NOTE
With manual selection, the LMF does not attempt to detect the test equipment to verify it is connected
and communicating with the LMF.
8 Click on Dismiss to close the LMF Options window.