User's Manual
Test Equipment Set-up68P09255A69-3
Aug 2002
1X SC4812ET Lite BTS Optimization/ATP Software Release 2.16.1.x
PRELIMINARY
3-49
Supported Test Equipment
CAUTION
To prevent damage to the test equipment, all transmit (TX) test
connections must be through a 30 dB directional coupler plus a
20 dB in-line attenuator for both the 800 MHz and 1.9 GHz
BTSs.
IS-95A/B Operation
Optimization and ATP testing for IS-95A/B sites or carriers may be
performed using the following test equipment:
CyberTest
Advantest R3267 spectrum analyzer with R3562 signal generator
Advantest R3465 spectrum analyzer with R3561L signal generator
and HP-437B or Gigatronics Power Meter
Agilent E4406A transmitter test set with E4432B signal generator
Agilent 8935 series E6380A communications test set (formerly HP
8935)
Hewlett-Packard HP 8921 (with CDMA interface and, for 1.9 GHz,
PCS Interface) and HP-437B or Gigatronics Power Meter
Spectrum Analyzer (HP8594E) - optional
Rubidium Standard Timebase - optional
CDMA2000 1X Operation
Optimization and ATP testing for CDMA2000 1X sites or carriers may
be performed using the following test equipment:
Advantest R3267 spectrum analyzer with R3562 signal generator
Agilent E4406A transmitter test set with E4432B signal generator
Agilent 8935 series E6380A communications test set (formerly HP
8935) with option 200 or R2K and with E4432B signal generator for
1X FER
Test Equipment Preparation
See Appendix F for specific steps to prepare each type of test set and
power meter to perform calibration and ATP .
3