User's Manual
Span Lines - Interface and Isolation68P09255A69-3
Aug 2002
1X SC4812ET Lite BTS Optimization/ATP Software Release 2.16.1.x
PRELIMINARY
3-13
T1/E1 Span Isolation
Table 3-5 describes the action required for span isolation.
Table 3-5: T1/E1 Span Isolation
Step Action
1 Have the OMCR/CBSC place the BTS OOS.
2 To disable the span lines, locate the connector for the span or spans which must be disabled and
remove the respective connector from the applicable SCCP cage Span I/O board (Figure 3-2).
Configure Optional Channel Service Units
The M-PATH 537 Channel Service Unit (CSU) module provides
in-band SNMP-managed digital service access to T1 and fractional T1
lines. The M-PATH 437 Channel Service Unit (CSU) module provides
in-band SNMP-managed digital service access to E1 and fractional E1
lines. CSU modules plug into the CSU shelf (see Figure 3-3).
The CSU shelf can support two M-PATH 537 or two M-PATH 437 CSU
modules. A 537 CSU module supports a single T1 span connection. A
437 CSU module supports a single E1 span connection.
Remote M-PATH management is available through SNMP over an
in-band data link on the span line (using a facility data link or
8-64 Kbps of a DS0 channel). The unit at the near end of the
management path can be an SNMP manager or another M-PATH CSU.
Programming of the M-PATH is accomplished through the DCE 9-pin
connector on the front panel of the CSU shelf. Manuals and an MS
Windows programming disk are supplied with each unit.
For more information refer to M-PATH T1 Channel Service Unit User’s
Guide, Kentrox part number 65-77538101 or the ADC M-PATH E1
Channel Service Unit User’s Guide, Kentrox part number 1174139.
Setting the Control Port
Whichever control port is chosen, it must first be configured so the
control port switch settings match the communication parameters being
used by the control device. If using the rear-panel DTE control port, set
the SHELF ADDRESS switch SA5 to “up.” If using the rear-panel DCE
control port, position the SHELF ADDRESS switch down.
For more information, refer to the 2-Slot Universal Shelf Installation
Guide, Kentrox part number 65-78070001, the M-PATH T1 Channel
Service Unit Installation Guide, Kentrox part number 65-77538001, or
the M-PATH E1 Channel Service Unit Installation Guide, Kentrox part
number 1174662, depending on installed equipment.
Plug one of the cables listed below into the Control Port connectors:
Part Number Description of Cable
01-95006-022 (six feet) DB-9S to DB-9P
01-95010-022 (ten feet)
The control port cables can be used to connect the shelf to:
3