User's Manual

Optimization/Calibraton - Introduction
68P09255A69-3
Aug 2002
1X SC4812ET Lite BTS Optimization/ATP Software Release 2.16.1.x
PRELIMINARY
3-4
NOTE
Refer to the Figure 3-1 and the LMF Help function on-line
documentation for additional information on the layout of the
LMF directory structure (including CDF file locations and
formats).
The CDF should be obtained from the CBSC. It can be provided on a
DOS-formatted diskette, or, if the LMF computer has file transfer
protocol (ftp) capability, through an ftp download. Refer to the LMF
Help function on-line documentation for more information.
CDF Site Equipage Verification
If it has not already been done, review and verify the site equipage data
in the CDF with the actual site hardware and the site engineering
documentation. Use a text editor to view the CDF contents.
CAUTION
- Use extreme care not to make any changes to the CDF
content while viewing the file. Changes to the CDF can
cause the site to operate unreliably or render it incapable of
operation.
- Always wear an approved anti-static wrist strap while
handling any circuit card/module to prevent damage by
ESD. Extreme care should be taken during the removal and
installation of any card/module. After removal, the
card/module should be placed on a conductive surface or
back into the anti-static packaging in which it was shipped.
BTS Software Release Download
The correct device initialization code (ROM code) for the Software
Release being used by the Base Station System (BSS) (for example
R16.0.x) must be successfully downloaded to the BTS processor boards
before optimization can be performed. Device initialization code is
normally downloaded to the processor boards from the CBSC using the
DownLoad Manager (DLM). For optimization, device application code
(RAM code) and data is loaded at the cell site from the LMF computer.
3