User's Manual

Required Test Equipment and Software
68P09255A69-3
Aug 2002
1X SC4812ET Lite BTS Optimization/ATP Software Release 2.16.1.x
PRELIMINARY
1-10
RF signal generator (capable of DSAT/CDMA modulation)
Audio signal generator
AC voltmeter (with 600-ohm balanced audio input and high
impedance input mode)
Noise measurement meter
C-Message filter
Spectrum analyzer
CDMA code domain analyzer
GPIB cables
Hewlett Packard 10833A or equivalent; one or two meters long, used to
interconnect test equipment and LMF computer.
CDMA2000 1X signal generators
Agilent E4432B signal generator (required for use with Agilent
E4406A when performing Frame Erasure Rate acceptance testing)
or
Advantest R3562 signal generator (required for use with Advantest
R3267 when performing Frame Erasure Rate acceptance testing)
Power meter
Hewlett Packard Model HP437B with HP8481A power sensor capable
of measuring from -30 dBm to 20 dBm
or
Gigatronics 8542B power meter
Timing reference cables
Two Huber & Suhner 16MCX/11BNC/K02252D or equivalent; right
angle MCX-male to standard BNC-male RG316 cables; 10 ft. long
are required to interconnect the communications system analyzer to
SGLN4132A and SGLN1145A CSM board timing references
or
Two BNC-male to BNC-male RG316 cables; 3 meters (10 feet) long,
used to interconnect the communications system analyzer to
SGLN4132B and SGLN1145B (and later) CSM front panel timing
references in the RF Modem Frame
Digital multimeter
Fluke Model 8062A with Y8134 test lead kit or equivalent; used for
precision DC and AC measurements to four decimal places.
Directional coupler
Narda Model 3020A 20 dB coupler terminated with two Narda Model
375BN-M loads, or equivalent.
RF attenuators
20 dB Fixed attenuator, 20 Watt (Narda 768-20), used in conjunction
with calibration of test cables or during general troubleshooting
procedures.