User's Manual

Test Equipment Preparation continued
08/01/2001
F-9
1X SCt4812ET Lite BTS Optimization/ATP
PRELIMINARY
R3465 GPIB Address & Clock
setup
Table F-7 describes the steps to set the GPIB address and clock for the
Advantest R3465 equipment.
Table F-7: Advantest R3465 GPIB Address and Clock Setup
Step Action
1 Communications test set GPIB address=18 (perform the following to view/set as required)
Perform the following to set the standard parameters on the test set:
S Push the SHIFT then PRESET pushbutton (just below the CRT display).
S Push the LCL pushbutton (CW in Measurement just below the CRT display)
Push the GPIB and Others CRT menu key to view the current address.
If required, change GPIB address to 18 (rotate the vernier knob to set, push the vernier knob to
enter)
2 Verify the current Date and Time in upper/right of the CRT display (perform the following to set if
required)
Communications test set GPIB address=18 (perform the following to view/set as required)
S Push the Date/Time CRT menu key
S If required, change to correct Date/Time (rotate the vernier knob to select and set, push the vernier
knob to enter)
S Push the SHIFT then PRESET pushbutton (just below the CRT display).
Pretest Setup for Advantest
R3465
Before the Advantest R3465 analyzer is used for LMF controlled testing
it must be set up correctly for automatic testing.
Table F-8: Pretest Setup for Advantest R346
Step Action
1 Press the SHIFT button so the LED next to it is illuminated.
2 Press the RESET button.
F