User's Manual

Power Delta Calibration continued
08/01/2001
H-13
1X SCt4812ET Lite BTS Optimization/ATP
PRELIMINARY
Table H-4: HP8921A Power Delta Calibration Procedure
Step Action
9 Set the measuring HP8921A as follows:
Measure mode to CDMA Anl
Frequency to the CDMA calibration target frequency
Input Attenuation to 0 dB
Input port to RFIN
Gain to Auto
Analyzer Direction to Fwd
10 Turn on the source HP8921A signal output.
11 Measure and record the channel power reading on the measuring HP8921A as result
B ________________________.
12 Turn off the source HP8921A signal output and disconnect the equipment.
13 Compute the delta between HP437 and HP8921A using the following formula:
Delta = A B
Example: Delta = 0.70 dBm (1.25 dBm) = 0.55 dBm
Example: Delta = 0.26 dBm 0.55 dBm = 0.29 dBm
These examples are included to show the mathematics and do not represent actual readings.
NOTE
Add this delta value to the TX Cable Loss value during InService Calibration (see Step 4 in
Table H-6).
Figure H-7: Delta Calibration Setup HP8921A to HP437
Short RF Cable
HP 8921A
DUPLEX
OUT
HP437B
Power
Sensor
SENSOR
FW00801
H