Acceptance Tests - Test Set-up
68P09255A69-3
Aug 2002
1X SC4812ET Lite BTS Optimization/ATP Software Release 2.16.1.x
PRELIMINARY
4-8
Companion frame All TX/RX, All RX, and FER for Diversity RX -
When performing All TX/RX, All RX, or FER ATP for companion
frame diversity RX, perform the additional test equipment set-up
procedures in Table 4-4.
Table 4-4: Additional Diversity RX Test Set-up for Companion Frames
Step Action
1 If the LMF is logged into the BTS, log out of the BTS.
2 If the inter-frame diversity RX cabling to a collocated companion frame is:
Connected to the companion frame under test, proceed to step 3.
Disconnected from the companion frame under test, proceed to step 7.
3 For companion frames with inter-frame diversity RX cables connected, click on the LMF Login tab.
4 In the Equipage Information box, select MPC from the Multi-Channel Preselector picklist.
5 Make RX test cable connections for diversity RX FER according to Figure 4-1 and Table 4-1.
6 Proceed to step 10.
7 For companion frames with inter-frame diversity RX cables disconnected, click on the LMF Login
tab.
8 In the Equipage Information box, select EMPC from the Multi-Channel Preselector picklist.
9 Make RX test cable connections for diversity RX FER according to Figure 4-1 and Table 4-2.
10 Click on the LMF BTS# tab, and return to the procedure for the ATP being performed.
4