Troubleshooting: Calibration
Bay Level Offset Calibration Failure
Table 6-11: Troubleshooting BLO Calibration Failure
Step Action
1 Verify the power meter or communications system analyzer is configured correctly (see the Test
Equipment Set-up section of Chapter 3), and is connected to the proper BTS TX antenna
connector.
2 If a power meter is being used:
2a - Re-calibrate the Power Meter and verify it is calibrated correctly with cal factors from the
power sensor (refer to Appendix F).
2b - Verify the power sensor is functioning properly by checking it with the 1-mW (0 dBm) Power
Ref signal.
2c - Verify communication between the LMF and Power Meter is working by checking that the
meter display is showing RES :
3 Verify the parameters in the bts-#.cdf file are set correctly for the BTS operating band as
follows:
For 1900 MHz:
Bandclass=1; Freq_Band=16
For 800 MHz:
Bandclass=0; Freq_Band=8
4 Verify that no LPA on the carrier is in alarm state (rapidly flashing red LED).
4a - If any are, reset the LPA(s) by pulling the applicable circuit breaker on the DC PDA, and,
after 5 seconds, pushing back in.
5 Verify GPIB adapter is not locked up. Under normal conditions, only 2 green LEDs must be ON
(Power and Ready). If any other LED is continuously ON, power-cycle (turn power off and on)
the GPIB Box and retry.