User's Manual
Abbreviated (All-inclusive) Acceptance Tests68P09255A69-3
Aug 2002
1X SC4812ET Lite BTS Optimization/ATP Software Release 2.16.1.x
PRELIMINARY
4-13
Table 4-7: All RX ATP Test Procedure
Step Action
8
In the Rate Set box, select the appropriate data rate (1=9600, 2=14400, 3=9600 1X) from the
drop-down list.
NOTE
The Rate Set selection of 1 is only available if non-1X cards are selected for the test.
The Rate Set selection of 3 is only available if 1X cards are selected for the test.
9 Enter the channel elements to be tested for the RX ATP in the Channel Element(s) box. By default,
all channel elements are specified.
Use one of thefollowing methods to enter more than one channel element:
- Enter non-sequential channel elements separated by a comma and no spaces (for example;
0,5,15).
- Enter a range of sequential channel elements by typing the first and last channel elements
separated by two periods (for example; 0..15).
NOTE
The channel element numbers are 0.based; that is the first channel element is 0.
10 Click OK to display a status bar followed by a Directions pop-up window.
11
NOTE
When testing diversity RX paths on companion frames, be sure to follow the RX test cable connection
information in Table 4-1 or Table 4-2, as applicable, during this step.
Follow cable connection directions as they are displayed, and click the Continue button to begin
testing.
- When the ATP process is completed, results will be displayed in the status report window.
12 Click the Save Results or Dismiss button.
NOTE
If Dismiss is used, the test results will not be saved in the test report file.
4