User's Manual
Abbreviated (All-inclusive) Acceptance Tests
68P09255A69-3
Aug 2002
1X SC4812ET Lite BTS Optimization/ATP Software Release 2.16.1.x
PRELIMINARY
4-12
Table 4-6: All TX ATP Test Procedure
Step Action
8 Click OK to display a status bar followed by a Directions pop-up window.
9 Follow cable connection directions as they are displayed, and click the Continue button to begin
testing.
- As the ATP process is completed, results will be displayed in the status report window.
10 Click the Save Results or Dismiss button.
NOTE
If Dismiss is used, the test results will not be saved in the test report file.
All RX ATP Test
Follow the procedure in Table 4-7 to perform the abbreviated,
all-inclusive receive test.
Table 4-7: All RX ATP Test Procedure
Step Action
1 Set up the test equipment for abbreviated tests per Table 4-3.
2
If a companion frame is being tested and either BOTH or DIV is to be selected in step 7, perform the
additional test equipment set-up in Table 4-4 for the diversity RX portion of the ATP.
NOTE
If the LMF has been logged into the BTS with a different Multi-Channel Preselector setting than the
one to be used for this test, the LMF must be logged out of the BTS and logged in again with the new
Multi-Channel Preselector setting. Using the wrong MPC setting can cause a false test failure.
3 Select the BBXs and MCCs to be tested.
4 Click on Tests in the BTS menu bar, and select All RX ATP... from the pull-down menu.
5
Select the appropriate carrier(s) and sector(s) (carrier-bts#-sector#-carrier#) from those displayed in the
Channels/Carrier pick list.
NOTE
To select multiple items, hold down the Shift or Ctrl key while clicking on pick list items to select
multiple carrier(s)-sector(s).
6
Verify that the correct channel number for the selected carrier is shown in the Carrier # Channels
box.
- If it is not, obtain the latest bts-#.cdf and cbsc-#.cdf files from the CBSC.
NOTE
If necessary, the correct channel number may be manually entered into the Carrier # Channels box.
7
NOTE
If a companion frame with the inter-frame diversity RX cabling disconnected is being tested do not
select BOTH in this step. The RX main and diversity paths must be tested separately for this
configuration because each requires a different Multi-Coupler Preselector type to provide the proper
test signal gain.
Select the appropriate RX branch (BOTH, MAIN, or DIVersity) in the drop-down list.
. . . continued on next page
4