1X SC 4812T BTS Optimization/ATP Software Release 2.16.1.x
FIELD TRIAL
3-14
Table 3-6: Pinging the Processors
Step Action
1 If you have not already done so, connect the LMF to the BTS (see Table 3-2 on page 3-6).
2 From the Windows desktop, click the Start button and select Run.
3 In the Open box, type ping and the <MGLI IP address> (for example, ping 128.0.0.2).
NOTE
128.0.0.2 is the default IP address for MGLI-1 in field BTS units. 128.0.0.1 is the default IP
address for MGLI-2.
4 Click on the OK button.
5 If the connection is successful, text similar to the following is displayed:
Reply from 128 128.0.0.2: bytes=32 time=3ms TTL=255
If there is no response the following is displayed:
Request timed out
If the MGLI fails to respond, reset and perform the ping process again. If the MGLI still fails to
respond, typical problems are shorted BNC to inter-frame cabling, open cables, crossed A and B
link cables, missing 50-Ohm terminators, or the MGLI itself.