User's Manual

Table Of Contents
Optimization/Calibration - Introduction
68P09255A61-4
Aug 2002
1X SC 4812T BTS Optimization/ATP Software Release 2.16.1.x
FIELD TRIAL
3-4
NOTE
Refer to the CDMA LMF Operators Guide for additional
information on the layout of the LMF directory structure
(including CDF file locations and formats).
BTS System Software Download
BTS system software must be successfully downloaded to the BTS
processor boards before optimization can be performed. BTS operating
code is loaded from the LMF computer terminal.
NOTE
Before using the LMF for optimization/ATP, the correct
bts-#.cdf and cbsc-#.cdf files for the BTS must be obtained
from the CBSC and put in a bts-# folder in the LMF. Failure to
use the correct CDF files can cause wrong results. Failure to use
the correct CDF files to log into a live (traffic carrying) site
can shut down the site.
The CDF is normally obtained from the CBSC on a DOS formatted
diskette, or through a file transfer protocol (ftp) if the LMF computer has
ftp capability. Refer to the CDMA LMF Operators Guide, or the LMF
Help screen, for the procedure.
Site Equipage Verification
If you have not already done so, use an editor to view the CDF, and
review the site documentation. Verify the site engineering equipage data
in the CDF matches the actual site hardware using a CDF conversion
table.
CAUTION
Always wear a conductive, high impedance wrist strap while
handling any circuit card/module to prevent damage by ESD.
Extreme care should be taken during the removal and installation
of any card/module. After removal, the card/module should be
placed on a conductive surface or back into the anti-static bag in
which it was shipped.
3