Optimization/Calibration - Introduction
Introduction
This section describes procedures for isolating the BTS from the span
lines, preparing and using the LMF, downloading system operating
software, CSM reference verification/optimization, set up and calibration
of the supported test equipment, transmit/receive path verification, using
the RFDS, and verifying the customer defined alarms and relay contacts
are functioning properly.
NOTE
Before using the LMF, use an editor to view the CAVEATS
section in the readme.txt file in the c:\wlmf folder for any
applicable information.
Optimization Process
After a BTS is physically installed and the preliminary operations
(power up) have been completed, use the LMF to calibrate and optimize
the BTS. Motorola recommends that the optimization be accomplished
as follows:
1. Download MGLI-1 with code and data and then enable MGLI-1.
NOTE GLIs may be GLI2s or GLI3s.
2. Use the status function and verify that all of the installed devices of
the following types respond with status information: CSM, BBX,
GLI, MCC, and TSU (if RFDS is installed). If a device is installed
and powered up but is not responding and is colored gray in the BTS
display, the device is not listed in the CDF file. The CDF file must
be corrected before the device can be accessed by the LMF.
3. Download code and data to all devices of the following types:
- CSM
- BBX (may be BBX2 or BBX-1X)
- GLI (other than MGLI-1)
- MCC (may be MCC-8E, MCC24, or MCC-1X)
4. Download the RFDS TSIC (if installed).
5. Verify the operation of the GPS and HSO or LFR signals.
6. Enable the following devices (in the order listed):
- Secondary CSM
- Primary CSM
- All MCCs
7. Connect the required test equipment for a full optimization.
8. Select the test equipment.
9. Calibrate the TX and RX test cables if they have not previously been
calibrated using the CDMA LMF that will be used for the
optimization/calibration. The cable calibration values can also be
entered manually.
3