User's Manual

Table Of Contents
CDMA 2000 Test Equipment Preparation68P09255A61-4
Aug 2002
1X SC 4812T BTS Optimization/ATP Software Release 2.16.1.x
FIELD TRIAL
J-13
Figure J-9: Setting Agilent E4406A GPIB Address
System Key Bk Sp Key
Enter Key
Data Entry
Keypad
Softkey
Buttons
Softkey Label
Display Area
Active Function
Area
ti-CDMA-WP-00085-v01-ildoc-ftw
Agilent E4432B Signal Generator GPIB Address
Follow the procedure in Table J-9 and refer to Figure J-10 to verify and,
if necessary, change the Agilent E4432B GPIB address.
Table J-9: Verify and Change Agilent E4432B GPIB Address
Step Action
1 In the MENUS section of the instrument front panel, press the Utility key.
- The softkey labels displayed on the right side of the instrument screen will change.
2 Press the GPIB/RS232 softkey button to the right of the instrument screen.
- The softkey labels will change.
- The current instrument GPIB address will be displayed below the GPIB Address softkey label.
3 If the current GPIB address is not set to 1, perform the following to change it:
3a - Press the GPIB Address softkey button.
-- The GPIB Address label and current GPIB address will change to boldface.
-- In the on-screen Active Entry Area, Address: will be displayed followed by the current
GPIB address.
. . . continued on next page