User's Manual

Table Of Contents
CDMA 2000 Test Equipment Preparation
68P09255A61-4
Aug 2002
1X SC 4812T BTS Optimization/ATP Software Release 2.16.1.x
FIELD TRIAL
J-10
CDMA 2000 Test Equipment Preparation
Advantest R3267 Spectrum Analyzer GPIB Address
Perform the procedure in Table J-7 and refer to Figure J-7 to verify and,
if necessary, change the Advantest R3267 spectrum analyzer GPIB
address.
Table J-7: Verify and Change Advantest R3267 GPIB Address
Step Action
1 If the REMOTE LED is lighted, press the LCL key.
- The LED extinguishes.
2 Press the CONFIG key.
- The CONFIG softkey labels will appear in the softkey label display area of the instrument
display.
- The current GPIB address will be displayed below the GPIB Address softkey label.
3 If the current GPIB address is not set to 18, perform the following to change it:
3a - Press the GPIB Address softkey.
-- A GPIB Address entry window will open in the instrument display showing the current
GPIB address.
3b
- Enter 18 on the keypad in the ENTRY section of the instrument front panel.
-- Characters typed on the keypad will replace the address displayed in the GPIB Address
entry window.
NOTE
To correct an entry, press the BS (backspace) key at the lower right of the keypad to delete one
character at a time.
3c - Press the ENTER key to the lower right of the keypad to enter the address.
-- The GPIB Address entry window closes.
-- The new address is displayed in the bottom portion of the GPIB Address softkey label.
J