User's Manual

Table Of Contents
GPIB Addresses68P09255A61-4
Aug 2002
1X SC 4812T BTS Optimization/ATP Software Release 2.16.1.x
FIELD TRIAL
J-5
HP8935 Test Set GPIB Address
Follow the procedure in Table J-4 to verify and, if necessary, change the
HP8935 GPIB address.
NOTE
This procedure assumes that the test equipment is set up and
ready for testing.
Table J-4: Verify and/or Change HP8935 GPIB Address
Step Action
* IMPORTANT
The HP I/O configuration MUST be set to Talk & Listen, or NO device on the GPIB bus will be
accessible. (Consult test equipment OEM documentation for additional information as required.)
1 To verify that the GPIB addresses are set correctly, press Shift and LOCAL on the HP8935 (see
Figure J-3). The current HP-IB address is displayed at the top of the screen.
NOTE
HP-IB is the same as GPIB.
2 If the current GPIB address is not set to 18, perform the following to change it:
- Press Shift and Inst Config.
- Turn the Cursor Control knob to move the cursor to the HP-IB Adrs field.
- Press the Cursor Control knob to select the field.
- Turn the Cursor Control knob as required to change the address to 18.
- Press the Cursor Control knob to set the address.
3
Press Preset to return to normal operation.
Figure J-3: HP8935 Test Set
FW00885
Preset
Cursor Control
Shift
Inst Config
Local
J