Table I-3: HP8935 Power Delta Calibration Procedure
Step Action
13 Calculate the Power Calibration Delta value. The delta value is the power meter measurement minus
the Advantest measurement.
Delta = A - B
Example: Delta = -0.70 dBm - (-1.25 dBm) = 0.55 dBm
Example: Delta = 0.26 dBm - 0.55 dBm = -0.29 dBm
These examples are included to show the mathematics and do not represent actual readings.
NOTE
Add this delta value to the TX Cable Loss value during In-Service Calibration (see Step 4 in
Table I-5).
Figure I-5: Delta Calibration Setup - HP8935 to HP437B
Power
Sensor
Hewlett-Packard Model HP 8935
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
ÁÁ
DUPLEX OUT
Short RF Cable
HP437B
SENSOR
FW00805