User's Manual
Table Of Contents
- Table of Contents
- List of Figures
- List of Tables
- Foreword
- FCC Requirements
- General Safety
- Revision History
- Patent Notification
- Chapter 1 Introduction
- Chapter 2 Preliminary Operations
- Chapter 3 Optimization/Calibration
- Optimization/Calibration - Introduction
- Isolate Span Lines/Connect LMF
- Preparing the LMF
- Using CDMA LMF
- Download the BTS
- CSM System Time/GPS and LFR/HSO Verification
- Test Equipment Set-up
- Test Set Calibration
- Bay Level Offset Calibration
- RFDS Set-up and Calibration
- BTS Redundancy/Alarm Testing
- BTS Alarms Testing
- Preliminary Operations: Overview
- Pre-Power-up Tests
- Initial Power-up Tests
- Chapter 4 Automated Acceptance Test Procedure
- Automated Acceptance Test Procedures - All-inclusive TX & RX
- TX Output Acceptance Tests: Introduction
- TX Spectral Purity Transmit Mask Acceptance Test
- TX Waveform Quality (rho) Acceptance Test
- TX Pilot Time Offset Acceptance Test
- TX Code Domain Power/Noise Floor Acceptance Test
- RX Frame Error Rate (FER) Acceptance Test
- Generate an ATP Report
- Chapter 5 Prepare to Leave the Site
- Chapter 6 Basic Troubleshooting
- Basic Troubleshooting Overview
- Troubleshooting: Installation
- Troubleshooting: Download
- Troubleshooting: Calibration
- Troubleshooting: Transmit ATP
- Troubleshooting: Receive ATP
- Troubleshooting: CSM Check-list
- C-CCP Backplane Troubleshooting
- Module Front Panel LED Indicators and Connectors
- Basic Troubleshooting - Span Control Link
- Appendix A Data Sheets
- Appendix B PN Offset/I & Q Offset Register Programming Information
- Appendix C FRU Optimization/ATP Test Matrix
- Appendix D BBX Gain Set Point vs. BTS Output
- Appendix E CDMA Operating Frequency
- Appendix F PCS Interface Setup for Manual Testing
- Appendix G VSWR
- Appendix H Download ROM Code
- Appendix I In-Service Calibration
- Appendix J GPIB Addresses
- Introduction
- HP437 Power Meter GPIB Address
- Gigatronics 8541C Power Meter GPIB Address
- Motorola CyberTest GPIB Address
- HP8935 Test Set GPIB Address
- Setting HP8921A and HP83236A/B GPIB Address
- Advantest R3465 GPIB Address
- RS232 GPIB Interface Box
- Advantest R3267 Spectrum Analyzer GPIB Address
- Agilent E4406A Transmitter Tester GPIB Address
- Index
Transmit & Receive Antenna VSWR68P09255A61-4
Aug 2002
1X SC 4812T BTS Optimization/ATP Software Release 2.16.1.x
FIELD TRIAL
G-3
Equipment Setup - HP Test Set
Follow the procedure in Table G-1 to set up test equipment required to
measure and calculate the VSWR for each antenna.
Table G-1: VSWR Measurement Procedure - HP Test Set
Step Action HP TEST SET
1 If you have not already done so, refer to the procedure in Table 3-2 on page 3-6 to set up test
equipment & interface the LMF computer to the BTS.
2 For manual VSWR testing, using external directional coupler, refer to Figure G-1 (1700/1900 MHz)
or Figure G-2 (800 MHz).
- Connect the communications test set RF OUT ONLY port to the INPUT port of the directional
coupler.
- Connect the RF IN/OUT port of the communication test set to the reverse (RVS) port on the
directional coupler. Terminate the forward port with a 50 ohm load.
- Install the antenna feed line to the output port on the directional coupler.
NOTE
Manual Communications Analyzer test setup (fields not indicated remain at default):
Set screen to RF GEN.
- For 1900 MHz systems, set the RF Gen Freq to center frequency of actual CDMA carrier
between 1930-1990 MHz for TX and 1850-1910 MHz for RX. For 800 MHz systems, set the
RF Gen Freq to center frequency of actual CDMA carrier between 869-894 MHz for TX and
824-849 MHz for RX. For 1700 MHz systems, set the RF Gen Freq to center frequency of
actual CDMA carrier between 1840-1870 MHz for TX and 1750-1780 MHz for RX.
- Set Amplitude to -30 dBm.
- Set Output Port to RF OUT.
- Set AFGen1 & AFGen2 to OFF.
3 Remove the antenna feed line and install an “RF short” onto the directional coupler output port.
NOTE
Set-up communication test set as follows (fields not indicated remain at default):
Set screen to SPEC ANL.
- Under Controls, set input port to ANT.
-
Set Ref Level to -40 dBm.
- Under Controls, select Main, select Auxiliary.
- Under Controls, select AV G. Set Avg = 20.
4 - Record the reference level on the communications analyzer and Note as P
S
for reference.
- Replace the short with the antenna feedline. Record the reference level on the communications
analyzer and Note for as P
A
reference.
- Record the difference of the two readings in dB.
. . . continued on next page