Aug 2002
1X SC 4812T BTS Optimization/ATP Software Release 2.16.1.x
FIELD TRIAL
F-6
Table F-2: Manual Cable Calibration Test Equipment Setup (using the HP PCS Interface)
Step Action
23 Click on Pause for Manual Measurement.
24 Verify the HP8921A Communication Analyzer/83203A CDMA interface setup is as follows (fields
not indicated remain at default):
Verify the GPIB (HP-IB) address:
- under To Screen, select More
- select IO CONFIG
- Set HP-IB Adrs to 18
- set Mode to Talk&Lstn
Verify the HP8921A is displaying frequency (instead of RF channel)
- Press the blue
[SHIFT] button, then press the Screen Control [DUPLEX] button; this switches to
the CONFIG (CONFIGURE) screen.
- Use the cursor control to set RF Display to Freq
25 Refer to Table 3-31 for assistance in manually setting the cable loss values into the LMF.
F