User's Manual

Table Of Contents
Optimization (Pre-ATP) Data Sheets
68P09255A61-4
Aug 2002
1X SC 4812T BTS Optimization/ATP Software Release 2.16.1.x
FIELD TRIAL
A-12
Table A-11: TX BLO Calibration (3-S: 2-C Adjacent Channels)
OK CommentsSpecificationParameter
BBX-7, ANT-4 = dB
BBX-r, ANT-4 = dB
Calibrate
carrier 2
TX Bay Level Offset = 42 dB (typical),
38 dB (minimum) prior to calibration
BBX-8, ANT-5 = dB
BBX-r, ANT-5 = dB
BBX-9, ANT-6 = dB
BBX-r, ANT-6 = dB
BBX-1, ANT-1 = dB
BBX-r, ANT-1 = dB
Calibration
Audit
carrier 1
0 dB (+0.5 dB) for gain set resolution
post calibration
BBX-2, ANT-2 = dB
BBX-r, ANT-2 = dB
carrier 1
BBX-3, ANT-3 = dB
BBX-r, ANT-3 = dB
BBX-7, ANT-4 = dB
BBX-r, ANT-4 = dB
Calibration
Audit
carrier 2
0 dB (+0.5 dB) for gain set resolution
post calibration
BBX-8, ANT-5 = dB
BBX-r, ANT-5 = dB
carrier 2
BBX-9, ANT-6 = dB
BBX-r, ANT-6 = dB
Comments:________________________________________________________
__________________________________________________________________
3-Carrier Adjacent Channels
4-Carrier Adjacent Channels
Table A-12: TX BLO Calibration (3-S: 3- or 4-C Adjacent Channels)
OK Parameter Specification Comments
BBX-1, ANT-1 = dB
BBX-r, ANT-1 = dB
Calibrate
carrier 1
TX Bay Level Offset = 42 dB (+4 dB)
prior to calibration
BBX-2, ANT-2 = dB
BBX-r, ANT-2 = dB
BBX-3, ANT-3 = dB
BBX-r, ANT-3 = dB
. . . continued on next page
A