User's Manual

Table Of Contents
Module Front Panel LED Indicators and Connectors
68P09255A61-4
Aug 2002
1X SC 4812T BTS Optimization/ATP Software Release 2.16.1.x
FIELD TRIAL
6-24
STATUS
Flashing GREEN- GLI2 is in service (INS), in a stable operating
condition.
On - GLI2 is in OOS RAM state operating downloaded code.
Off - GLI2 is in OOS ROM state operating boot code.
SPANS
Solid GREEN - Span line is connected and operating.
Solid RED - Span line is disconnected or a fault condition exists.
GLI2 Pushbuttons and Connectors
RESET Pushbutton - Depressing the RESET pushbutton
causes a partial reset of the CPU and a reset of all board devices.
The GLI2 is placed in the OOS_ROM state
MMI Connector - The RS-232MMI port connector is intended
to be used primarily in the development or factory environment
but may be used in the field for debug/maintenance purposes.
LAN Connectors (A & B) - The two 10BASE2 Ethernet circuit
board mounted BNC connectors are located on the bottom front
edge of the GLI2; one for each LAN interface, A & B. Ethernet
cabling is connected to tee connectors fastened to these BNC
connectors.