User's Manual
Table Of Contents
- Table of Contents
- List of Figures
- List of Tables
- Foreword
- FCC Requirements
- General Safety
- Revision History
- Patent Notification
- Chapter 1 Introduction
- Chapter 2 Preliminary Operations
- Chapter 3 Optimization/Calibration
- Optimization/Calibration - Introduction
- Isolate Span Lines/Connect LMF
- Preparing the LMF
- Using CDMA LMF
- Download the BTS
- CSM System Time/GPS and LFR/HSO Verification
- Test Equipment Set-up
- Test Set Calibration
- Bay Level Offset Calibration
- RFDS Set-up and Calibration
- BTS Redundancy/Alarm Testing
- BTS Alarms Testing
- Preliminary Operations: Overview
- Pre-Power-up Tests
- Initial Power-up Tests
- Chapter 4 Automated Acceptance Test Procedure
- Automated Acceptance Test Procedures - All-inclusive TX & RX
- TX Output Acceptance Tests: Introduction
- TX Spectral Purity Transmit Mask Acceptance Test
- TX Waveform Quality (rho) Acceptance Test
- TX Pilot Time Offset Acceptance Test
- TX Code Domain Power/Noise Floor Acceptance Test
- RX Frame Error Rate (FER) Acceptance Test
- Generate an ATP Report
- Chapter 5 Prepare to Leave the Site
- Chapter 6 Basic Troubleshooting
- Basic Troubleshooting Overview
- Troubleshooting: Installation
- Troubleshooting: Download
- Troubleshooting: Calibration
- Troubleshooting: Transmit ATP
- Troubleshooting: Receive ATP
- Troubleshooting: CSM Check-list
- C-CCP Backplane Troubleshooting
- Module Front Panel LED Indicators and Connectors
- Basic Troubleshooting - Span Control Link
- Appendix A Data Sheets
- Appendix B PN Offset/I & Q Offset Register Programming Information
- Appendix C FRU Optimization/ATP Test Matrix
- Appendix D BBX Gain Set Point vs. BTS Output
- Appendix E CDMA Operating Frequency
- Appendix F PCS Interface Setup for Manual Testing
- Appendix G VSWR
- Appendix H Download ROM Code
- Appendix I In-Service Calibration
- Appendix J GPIB Addresses
- Introduction
- HP437 Power Meter GPIB Address
- Gigatronics 8541C Power Meter GPIB Address
- Motorola CyberTest GPIB Address
- HP8935 Test Set GPIB Address
- Setting HP8921A and HP83236A/B GPIB Address
- Advantest R3465 GPIB Address
- RS232 GPIB Interface Box
- Advantest R3267 Spectrum Analyzer GPIB Address
- Agilent E4406A Transmitter Tester GPIB Address
- Index
Prepare to Leave the Site68P09255A61-4
Aug 2002
1X SC 4812T BTS Optimization/ATP Software Release 2.16.1.x
FIELD TRIAL
5-9
LMF Removal
CAUTION
DO NOT power down the LMF without performing the
procedure indicated below. Corrupted/lost data files may result,
and in some cases, the LMF may lock up.
Follow the procedure in Table 5-7 to terminate the LMF session and
remove the terminal.
Table 5-7: LMF Termination and Removal
Step Action
1 From the CDMA window select File>Exit.
2 From the Windows Task Bar click Start>Shutdown.
Click Yes when the Shut Down Windows message appears.
3 Disconnect the LMF terminal Ethernet connector from the BTS cabinet.
4 Disconnect the LMF serial port, the RS-232 to GPIB interface box, and the GPIB cables as
required for equipment transport.
Copying CAL Files from Diskette to the CBSC
Follow the procedure in Table 5-8 to copy CAL files from a diskette to
the CBSC.
Table 5-8: Procedures to Copy CAL Files from Diskette to the CBSC
Step Action
1 Login to the CBSC on the workstation using your account name and password.
NOTE
Enter the information that appears in bold text.
2 Place your diskette containing CAL file(s) in the CBSC workstation diskette drive.
3 Type eject -q and press the <Enter> key.
4 Type mount and press the <Enter> key.
Verify that floppy/no_name is displayed.
NOTE
If the eject command has been previously entered, floppy/no_name will be appended with a
number
. Use the explicit floppy/no_name reference displayed.
5 Enter cd /floppy/no_name and press the <Enter> key.
6 Enter ls -lia and press the <Enter> key.
Verify that the bts-#.cal file is on the diskette.
7 Enter cd and press the <Enter> key.
8 Enter pwd and press the <Enter> key.
Verify that you are in your home directory (/home/<name>).
9 Enter dos2unix /floppy/no_name/bts-#.cal bts-#.cal and press the <Enter> key (where # is the
BTS number).
. . . continued on next page
5