User's Manual
Table Of Contents
- Table of Contents
- List of Figures
- List of Tables
- Foreword
- FCC Requirements
- General Safety
- Revision History
- Patent Notification
- Chapter 1 Introduction
- Chapter 2 Preliminary Operations
- Chapter 3 Optimization/Calibration
- Optimization/Calibration - Introduction
- Isolate Span Lines/Connect LMF
- Preparing the LMF
- Using CDMA LMF
- Download the BTS
- CSM System Time/GPS and LFR/HSO Verification
- Test Equipment Set-up
- Test Set Calibration
- Bay Level Offset Calibration
- RFDS Set-up and Calibration
- BTS Redundancy/Alarm Testing
- BTS Alarms Testing
- Preliminary Operations: Overview
- Pre-Power-up Tests
- Initial Power-up Tests
- Chapter 4 Automated Acceptance Test Procedure
- Automated Acceptance Test Procedures - All-inclusive TX & RX
- TX Output Acceptance Tests: Introduction
- TX Spectral Purity Transmit Mask Acceptance Test
- TX Waveform Quality (rho) Acceptance Test
- TX Pilot Time Offset Acceptance Test
- TX Code Domain Power/Noise Floor Acceptance Test
- RX Frame Error Rate (FER) Acceptance Test
- Generate an ATP Report
- Chapter 5 Prepare to Leave the Site
- Chapter 6 Basic Troubleshooting
- Basic Troubleshooting Overview
- Troubleshooting: Installation
- Troubleshooting: Download
- Troubleshooting: Calibration
- Troubleshooting: Transmit ATP
- Troubleshooting: Receive ATP
- Troubleshooting: CSM Check-list
- C-CCP Backplane Troubleshooting
- Module Front Panel LED Indicators and Connectors
- Basic Troubleshooting - Span Control Link
- Appendix A Data Sheets
- Appendix B PN Offset/I & Q Offset Register Programming Information
- Appendix C FRU Optimization/ATP Test Matrix
- Appendix D BBX Gain Set Point vs. BTS Output
- Appendix E CDMA Operating Frequency
- Appendix F PCS Interface Setup for Manual Testing
- Appendix G VSWR
- Appendix H Download ROM Code
- Appendix I In-Service Calibration
- Appendix J GPIB Addresses
- Introduction
- HP437 Power Meter GPIB Address
- Gigatronics 8541C Power Meter GPIB Address
- Motorola CyberTest GPIB Address
- HP8935 Test Set GPIB Address
- Setting HP8921A and HP83236A/B GPIB Address
- Advantest R3465 GPIB Address
- RS232 GPIB Interface Box
- Advantest R3267 Spectrum Analyzer GPIB Address
- Agilent E4406A Transmitter Tester GPIB Address
- Index
BTS Alarms Testing68P09255A61-4
Aug 2002
1X SC 4812T BTS Optimization/ATP Software Release 2.16.1.x
FIELD TRIAL
3-107
Table 3-57: Pin and Signal Information for Alarm Connectors
ALARM A ALARM B
Pin Signal NamePinSignal NamePinSignal NamePinSignal Name
5 A CDO2 Com 35 Cust Retn 6 5 B CDO10 Com 35 B CDI 24
6 A CDO2 NO 36 A CDI 6 6 B CDO10 NO 36 Cust Retn 24
7 A CDO3 NC 37 Cust Retn 7 7 B CDO11 NC 37 B CDI 25
8 A CDO3 Com 38 A CDI 7 8 B CDO11 Com 38 Cust Retn 25
9 A CDO3 NO 39 Cust Retn 8 9 B CDO11 NO 39 B CDI 26
10 A CDO4 NC 40 A CDI 8 10 B CDO12 NC 40 Cust Retn 26
11 A CDO4 Com 41 Cust Retn 9 11 B CDO12 Com 41 B CDI 27
12 A CDO4 NO 42 A CDI 9 12 B CDO12 NO 42 Cust Retn 27
13 A CDO5 NC 43 Cust Retn 10 13 B CDO13 NC 43 B CDI 28
14 A CDO5 Com 44 A CDI 10 14 B CDO13 Com 44 Cust Retn 28
15 A CDO5 NO 45 Cust Retn 11 15 B CDO13 NO 45 B CDI 29
16 A CDO6 NC 46 A CDI 11 16 B CDO14 NC 46 Cust Retn 29
17 A CDO6 Com 47 Cust Retn 12 17 B CDO14 Com 47 B CDI 30
18 A CDO6 NO 48 A CDI 12 18 B CDO14 NO 48 Cust Retn 30
19 A CDO7 NC 49 Cust Retn 13 19 B CDO15 NC 49 B CDI 31
20 A CDO7 Com 50 A CDI 13 20 B CDO15 Com 50 Cust Retn 31
21 A CDO7 NO 51 Cust Retn 14 21 B CDO15 NO 51 B CDI 32
22 A CDO8 NC 52 A CDI 14 22 B CDO16 NC 52 Cust Retn 32
23 A CDO8 Com 53 Cust Retn 15 23 B CDO16 Com 53 B CDI 33
24 A CDO8 NO 54 A CDI 15 24 B CDO16 NO 54 Cust Retn 33
25 Cust Retn 1 55 Cust Retn 16 25 B CDI 19 55 B CDI 34
26 A CDI 1 56 A CDI 16 26 Cust Retn 19 56 Cust Retn 34
27 Cust Retn 2 57 Cust Retn 17 27 B CDI 20 57 B CDI 35
28 A CDI 2 58 A CDI 17 28 Cust Retn 20 58 Cust Retn 35
29 Cust Retn 3 59 Cust Retn 18 29 B CDI 21 (+27 V)
Converter Alarm (-48 V)
59 B CDI 36
30 A CDI 3 60 A CDI 18 30 Cust Retn 21 (+27 V)
Converter Retn (-48V)
60 Cust Retn 36
NOTE
CDO = Customer Defined Output
CDI = Customer Defined Input
3