User's Manual

Table Of Contents
RFDS Set-up and Calibration68P09255A61-4
Aug 2002
1X SC 4812T BTS Optimization/ATP Software Release 2.16.1.x
FIELD TRIAL
3-89
Table 3-46: RFDS Calibration Procedure
ActionStep
8 Select the appropriate carrier(s) in the Carriers pick list.
NOTE
Use the <Shift> or <Ctrl> key to select multiple carriers.
9 Select the appropriate Rx branch (Main, Diversity or Both) in the RX Branch pick list.
10 Click OK.
A status report window is displayed, followed by a Directions pop-up window.
11 Follow the cable connection directions as they are displayed.
A status report window displays the results of the actions.
12 Click on the OK button to close the status report window.
13 Click on the MGLI.
14 Download updated RFDS offset data to the selected GLI device by clicking on
Device>Download>Data from the tab menu bar and pull-down menu.
Program TSU NAM
Follow the procedure in Table 3-47 to program the TSU NAM. The
NAM must be programmed before it can receive and process test calls,
or be used for any type of RFDS test.
Prerequisites
Ensure the following prerequisites have been met before proceeding:
MGLI is INS.
TSU is powered up and has a code load.
Table 3-47: Program the TSU NAM
Step Action
1 Select the RFDS tab.
2 Select the SUA (Cobra RFDS) or TSU (GLI based RFDS).
3 Click on the TSU menu.
4 Click on the Program TSU NAM menu item.
5 Enter the appropriate information in the boxes (see Table 3-42 and Table 3-43).
6 Click on the OK button to display the status report.
7 Click on the OK button to close the status report window.
3