RFDS Parameter Settings
The bts-#.cdf file includes RFDS parameter settings that must
match the installed RFDS equipment. The paragraphs below describe the
editable parameters and their defaults. Table 3-41 explains how to edit
the parameter settings.
RfdsEquip - valid inputs are 0 through 2.
0 = (default) RFDS is not equipped
1 = Non-Cobra/Patzer box RFDS
2 = Cobra RFDS
TsuEquip - valid inputs are 0 or 1
0 = (default) TSU not equipped
1 = TSU is equipped in the system
MC1....4 - valid inputs are 0 or 1
0 = (default) Not equipped
1 = Multicouplers equipped in RFDS system
(9600 system RFDS only)
Asu1/2Equip - valid inputs are 0 or 1
0 = (default) Not equipped
1 = Equipped
TestOrigDN - valid inputs are ’’’ (default) or a numerical string up to
15 characters. (This is the phone number the RFDS dials when
originating a call. A dummy number needs to be set up by the switch,
and is to be used in this field.)
NOTE
Any text editor supporting the LMF may be used to open any
text files to verify, view, or modify data.