User's Manual

Table Of Contents
Bay Level Offset Calibration
68P09255A61-4
Aug 2002
1X SC 4812T BTS Optimization/ATP Software Release 2.16.1.x
FIELD TRIAL
3-80
Table 3-39: All Cal/Audit Test
ActionStep
7 From the Test Pattern pick list, select a test pattern.
NOTE
Selecting Pilot (default) performs tests using a pilot signal only.
Selecting Standard performs tests using pilot, synch, paging and 6 traffic channels. This
requires an MCC to be selected.
Selecting CDFPilot performs tests using a pilot signal, however, the gain for the channel
elements is specified in the CDF file.
Selecting CDF performs tests using pilot, synch, paging and 6 traffic channels, however, the
gain for the channel elements is specified in the CDF file.
8 Click on OK.
9 Follow the cable connection directions as they are displayed.
A status report window displays the test results.
10 Click on Save Results or Dismiss to close the status report window.
3