User's Manual

Table Of Contents
Test Equipment Set-up
68P09255A61-4
Aug 2002
1X SC 4812T BTS Optimization/ATP Software Release 2.16.1.x
FIELD TRIAL
3-44
CDMA 2000 Testing
NOTE
IS-95 C is the same as CDMA 2000.
Optimization and ATP testing may be performed using one of the
following test sets:
Advantest R3267 Analyzer with Advantest R3562 Signal Generator
Agilent E4406A with E4432B Signal Generator
Hewlett-Packard HP 8935 with option 200 or R2K for 1X TX and
with Agilent E4432B Signal Generator for 1X FER
The E4406A/E4432B pair, or the R3267/R3562 pair, should be
connected together using a GPIB cable. In addition, the R3562 and
R3267 should be connected with a serial cable from the Serial I/O to the
Serial I/O. This test equipment is capable of performing tests in both
IS-95 A/B mode and CDMA 2000 mode if the required options are
installed.
Optional test equipment
Spectrum Analyzer (HP8594E) - can be used to perform cable
calibration.
3