User's Manual

Table Of Contents
Download the BTS68P09255A61-4
Aug 2002
1X SC 4812T BTS Optimization/ATP Software Release 2.16.1.x
FIELD TRIAL
3-27
Download Code and Data to Non-GLI Devices
Non-GLI devices can be downloaded individually or all equipped
devices can be downloaded with one action. Follow the procedure in
Table 3-13 to download code and data to the non-GLI devices.
NOTE
- When downloading multiple devices, the download may
fail for some of the devices (a time out occurs). These
devices can be downloaded separately after completing the
multiple download.
- CSM devices are RAM code-loaded at the factory. RAM
code is downloaded to CSMs only if updating to a newer
software version.
Table 3-13: Download Code and Data to Non-GLI Devices
Step Action
1 Select all devices to be downloaded.
2 From the Device pull down menu, select Download>Code/Data.
A status report displays the result of the download for each selected device.
Click OK to close the status window.
NOTE
After the download has started, the device being downloaded changes to blue. If the download is
completed successfully, the device changes to yellow (OOS-RAM with code loaded).
After a BBX, CSM or MCC is successfully downloaded with code and has changed to
OOS-RAM, the status LED should be rapidly flashing GREEN.
NOTE
The command in Step 2 loads both code and data. Data can be downloaded without doing a code
download anytime a device is OOS-RAM using the command in Step 3.
3 To download the firmware application data to each device, select the target device and select:
Device>Download>Data
3