User's Manual

Attaching the Site I/O Junction Box to the Unit continued
DRAFT
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
JAN 2002
6-14
Figure 6-9: Attaching the Site I/O Junction Box to the Unit
SITE I/O JUNCTION BOX
CAPTIVE SCREWS
YGROUND CABLE (CABLE L) OR,
SITE I/O GROUND CABLE (CABLE B)
MASTER GROUND
CABLE (CABLE Y)
TO SU (IF EQUIPPED)
Procedure to Attach a Site I/O
Cap to the Unit (optional)
Use the following procedure in Table 6-8 to attach a Site I/O Cap to the
unit.
Table 6-8: Procedure to Attach a Site I/O Cap to the Unit (optional)
Step Action
1 Position the Site I/O cap, Motorola Part Number 1587667C06, over the Site I/O socket.
2 Use a T30 Torx tamper bit to tighten (but do not torque) the upper tamper resistant screw.
3 Tighten but do not torque the lower tamper resistant screw.
4 Use a T30 Torx tamper bit to torque the upper and lower screw to 5 Nm.