User's Manual

Site I/O, Span Line, RGPS, and Modem Cabling for Sites Equipped With
Primary Surge Suppressor
continued
JAN 2002
5-21
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
DRAFT
Table 5-14: Pin/Signal Information for Site I/O Cable and Punchdown Block
BTS Interface DescriptionPunchblock
Location
Sync Reverse OSP 11T 1 PPS to Tail
OSP 11R 1 PPS to Tail +
OSP 12T 1 PPS from Tail
Sync Reverse
OSP 12R 1 PPS from Tail +
OSP 13T Downstream BTS Detect +
OSP 13R Downstream BTS Detect
OSP 14T Data from Head
OSP 14R Data from Head +
OSP 15T Data to Head
OSP 15R Data to Head +
OSP 16T 1 PPS from Head
OSP 16R 1 PPS from Head +
Sync Forward
OSP 17T 1 PPS to Head
OSP 17R 1 PPS to Head +
OSP 18T RGPS 28V
OSP 18R RGPS Ground
OSP 19T RGPS 28V
OSP 19R RGPS Ground
OSP20T Unused
Unused
OSP20R Unused
OSP 21T RX TIP Primary (Network/Span A)
OSP 21R RX RING Primary (Network/Span A)
OSP 22T TX TIP Primary (Network/Span A)
Span (Network)
OSP 22R TX RING Primary (Network/Span A)
OSP 23T RX TIP Secondary (Network/Span B)
OSP 23R RX RING Secondary (Network/Span B)
OSP 24T TX TIP Secondary (Network/Span B)
Span (Network)
OSP 24R TX RING Secondary (Network/Span B)
. . . continued on next page
5