User's Manual

Power, Ground, and Battery Cabling for Sites Equipped with Optional
Primary Surge Suppressor
continued
JAN 2002
5-9
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
DRAFT
Required Cables
Table 5-2 provides the quantity and description of the required cables.
Table 5-2: Required Cables for Power, Earth Ground, and Battery Connections
Cable Qty. Part Number Description
A 14 3087701C02 Ground cable, 8 -AWG, insulated copper wire. Requires one ring lug
connector.
S 14 3087854C02 AC input cable, 14 AWG, 5 m, is designed for 88260 VAC power
input. Cable has Deutsche connector on both ends.
T 1 Customer
Supplied
AC Input power cable. 1014 AWG, 90C wire. Designed for
120240 VAC.
U 14 3087854C04 DC input cable, 14 and 22 AWG, 5 m, is designed for 20 to 30 VDC
power input.
Y 1 Customer
Supplied
Master Ground Cable, 6 -AWG, insulated copper wire.
AC Input Cable Information
The information for the AC input cable(s) (Cable S) is given in
Figure 5-6 and Table 5-3.
Figure 5-6: AC Input Cable Connector Information
A
B
C
SOCKET POSITION ON CABLE
CONNECTOR SHOWN
Table 5-3: AC Input Cable Information
Connector Wire Color Description
A Black Line
B Green Ground
C White Neutral
5