This procedure gives information to connect multiple BTS sites for both
RGPS (synchronous) and HSO (non–synchronous) configurations in
both indoor and outdoor applications.
Background
The RGPS only connects to the first unit of a multi–unit logical BTS.
This first unit sends timing signals to all other units. You only need to
connect the site I/O interfaces of each multi–unit logical BTS to each
other. This allows “sharing” of a single RGPS antenna between several
single or multi–unit logical BTSs.
This also applies to systems using HSO instead of RGPS. The HSO
timing is “shared” in the same way.
Required Tools and Equipment
Cables
The RGPS Synchronization Cable is contained in the Motorola kits
listed in Table 4-25:
Table 4-25: Required Cables for RGPS Cabling for Multiple BTS Sites
Cable Qty. Part Number Description
X 1–11
3086039H18 RGPS Synchronization cable (part of kit SGKN4351A).
3086039H19 RGPS Synchronization cable (part of kit SGKN4352A).
Motorola kits
Table 4-26 and Table 4-27 show the contents of Motorola kits
SGKN4351A and SGKN4352A. These kits are necessary for RGPS
cabling between multiple BTS locations.
Table 4-26: RGPS Synchronization Cable Kit – SGKN4351A
Cable Qty. Motorola Part
Number
Description
X 1 3086039H18 RGPS Sync Cable, 2000 ft.
n/a 2 5864461A03 Fitting, liquid tight.
n/a 2 0264599A02 Nut, nylon locking
Table 4-27: RGPS Synchronization Cable Kit – SGKN4352A
Cable Qty. Motorola Part
Number
Description
X 1 3086039H19 RGPS Sync Cable, 3280 ft.
n/a 2 5864461A03 Fitting, liquid tight.
n/a 2 0264599A02 Nut, nylon locking