User's Manual
TX Acceptance Tests – continued
JAN 2002
7-83
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
DRAFT
Figure 7-34: TX ATP Setup (Advantest R3267 and Agilent E4406A)
ANTENNA B
POWER METER
30DB IN-LINE ATTENUATOR
TRANSMIT RF
TEST CABLE
POWER SENSOR
NOTE: THE DOTTED LINES REPRESENT THAT
EITHER TX RF TEST CABLE CONNECTS TO
BOTH COMMUNICATIONS TEST SET AND
POWER METER
ADVANTEST R3267 SPECTRUM
ANALYZER 100Hz – 8GHz
ADVANTEST R3562 RECEIVER TEST
SOURCE
ADVANTEST R3267 (TOP)
AND R3562 (BOTTOM)
RF INPUT
INPUT 50 OHM
AGILENT E4432B (TOP)
AND E4406A (BOTTOM)