User's Manual
Test Equipment Calibration – continued
JAN 2002
7-55
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
DRAFT
Procedure to Setup Advantest
R3465 Test Equipment
Follow the steps outlined in Table 7-33 (for Advantest R3465) or
Table 7-34 (for Advantest R3267) to set up test equipment prior to
performing ATP tests.
LMF based measurements factor in cable and attenuator
loss between the BTS and test equipment. No additional
attenuation can be inserted as the additional losses would
not be factored in.
IMPORTANT
*
If you are logged in to the BTS, you must log out prior to
loading the special JCDMA software on a PCMCIA RAM
card and inserting it in the Advantest R3465 PCMCIA slot.
This must be done before using the Advantest R3465 test
set for JCDMA tests.
IMPORTANT
*
Table 7-33: Procedure to Setup Advantest R3465 Test Equipment
Step Action
1 If you have not already done so, interface the CDMA LMF computer to the BTS and login to the BTS.
2 Perform the following steps for the manual test procedure for Automated TX verification.
Set up the communication test set by inserting the Automatic TX test PCMCIA card into the
Advantest PCMCIA card reader slot A. (software version=97.10.07 rev 0001 or later).
Perform the following steps to access and use the Advantest Automatic TX test screen:
3 Press the Remote LCL button (located below the CRT).
4 Press the Loader ON button (located below the CRT).
5 Press the LOAD CRT menu button.
6 Use the DISPLAY CONTROL knob to select CDMA_BSR.BAS and then press the knob.
7 Press the RUN CRT menu button after the LOAD pop–up disappears.
8 Wait for *Idle Free space to appear at the bottom of the CRT.
9 Refer to Figure 7-34 to set up test equipment.
Verify that the coaxial cable from the appropriate TX connector on the BTS is connected to the test
equipment RF input port via the in line 30 dB high power attenuator for MicroCell BTSs.
7