User's Manual

Test Equipment Calibration continued
JAN 2002
7-53
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
DRAFT
Procedure to Calibrate R3465
Test Set
Follow the steps inTable 7-30 to configure and calibrate the R3465
communication test set.
Table 7-30: Procedure to Calibrate R3465
Step Action
1
* IMPORTANT
Perform this calibration only after the analyzer has warmedup and stabilized for a minimum
of 60 minutes. Test equipment warmup may vary depending on operating environment or
initial temperature of unit upon turnon. Consult test equipment OEM documentation for
additional information as required.
Connect the male BNC to male N cable between the CAL OUT connector and the INPUT 50 W
connector.
2 Select CW.
3 Push the SHIFT and CAL pushbuttons.
4 Select Cal All in CRT menu.
Internal calibration should complete in about 6 minutes.
Procedure to Calibrate R3267
Test Set
Follow the steps in Table 7-31 to configure and calibrate the R3267
communication test set.
Table 7-31: Procedure to Calibrate R3267
Step Action
1
* IMPORTANT
Perform this calibration only after the analyzer has warmedup and stabilized for a minimum
of 60 minutes. Test equipment warmup may vary depending on operating environment or
initial temperature of unit upon turnon. Consult test equipment OEM documentation for
additional information as required.
Connect the male BNC to male N cable between the CAL OUT connector and the INPUT 50 W
connector.
2 Select CW.
3 Push the SHIFT and CAL pushbuttons.
4 Select Cal All in CRT menu.
Internal calibration should complete in about 6 minutes.
7