User's Manual
GPIB Addresses – continued
JAN 2002
7-43
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
DRAFT
Verify and Set the HP8921A
and HP83236A/B GPIB
Addresses
Follow the procedure in Table 7-24 to verify and, if necessary, change
the HP8921A/HP83236A GPIB addresses.
Table 7-24: Verify and/or Change HP8921A and HP83236A GPIB Addresses
Step Action
1 To verify that the GPIB addresses are set correctly, press Shift and LOCAL on the HP8921A (refer to
Figure 7-20). The current HP–IB address is displayed at the top of the screen.
NOTE
HP–IB is the same as GPIB.
2 If the current HP–IB address is not set to 18, perform the following to change it:
– Turn the Cursor Control knob to move the cursor to More and press the knob to select the field.
– Turn the Cursor Control knob to move the cursor to I/O Config and press the knob to select the
field.
– Turn the Cursor Control knob to move the cursor to Adrs and press the knob to select the field.
– Turn the Cursor Control knob to change the HP–IB address to 18 and press the knob to set the
address.
– Press Shift and Preset to return to normal operation.
3 To set the HP83236A (or B) PCS Interface GPIB address=19, set the dip switches as follows:
– A1=1, A2=1, A3=0, A4=0, A5=1, HP–IB/Ser = 1
Preset
Cursor Control
Shift
Local
Figure 7-20: HP8921A and HP83236A/B
7