User's Manual

BTS Configuration continued
DRAFT
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
JAN 2002
7-24
Table 7-8: Procedure to Set IP Address
Step Action
6 Enter the following command at the sc300> prompt:
sc300>ether setgw 128.0.0.2
The system will display the following output:
COMMAND ACCEPTED: ether setgw 128.0.0.2
”128” ”0” ”0” ”2”
THESE ARE THE BYTES READ IN: 128.0.0.2
SETTING GW: 128.0.0.2
Completed flashing of Gateway address
CONFIRM NEW GW: 128.0.0.2
New parameters will take affect after next reset.
7 Enter the following command at the sc300> prompt:
sc300>ether setnm 255.255.255.255
The system will display the following output:
COMMAND ACCEPTED: ether setnm 255.255.255.255
”255” ”255” ”255” ”255”
THESE ARE THE BYTES READ IN: 255.255.255.255
SETTING NETMASK: 255.255.255.255
Completed flashing of SubnetMask address
CONFIRM NEW NETMASK: 255.255.255.255
New parameters will take affect after next reset.
8 Repeat steps 1 through 3 to verify your entries.
9 If your entries are correct, then press the red RESET button on the diagnostic access area to reset
the unit.
Procedure to Simulate an LMF
Session
You must start a simulated LMF session when you enter MMI
commands. Enter the following command at the MMI prompt to
simulate an LMF link:
sndtype 0xa178
You should enter this command at the beginning of every simulated
MMI Communication Session.
7