Connect Test Equipment to BTS – continued
JAN 2002
7-13
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
DRAFT
Procedure to Connect
Advantest R3267 to BTS
Use the procedures in Table 7-4 to connect the Advantest R3267 to the
BTS. Refer to Figure 7-12.
The Advantest R3267 test set is used for 1X system
testing.
NOTE
Table 7-4: Procedure to Connect Advantest R3267 to the BTS
Step Action
1 Connect an SMA/BNC coax cable between the following points:
– BNC on the MOD TIMEBASE IN port on the front panel of the Advantest R3562 Test
Source.
– SMA on the 19 MHz port on the diagnostic access area of the BTS.
2 Connect an SMA/BNC cable between the following points:
– SMA on the 2 Sec port on the diagnostic access area of the BTS.
– BNC to the EXT TRIG IN port on the front panel of the Advantest R3562 Test Source.
3 Verify the R3267 and R3562 rear panel connections are in place (These are common connections
and should already be installed):
– Serial cable between R3267 rear panel SERIAL I/O port and R3562 rear panel SERIAL I/O
port.
– SMA cable between R3267 rear panel 10MHZ REF OUT port and R3562 rear panel
SYNTHE REF IN port.
– SMA cable between R3267 rear panel EXT TRIG port and R3562 rear panel CLOCK OUT
1 port.
– Parallel cable between R3267 rear panel GPIB port and R3562 GPIB port.