User's Manual

Release 15 Alarm List
JAN 2002
B-1
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
DRAFT
Objective
Table B-1 lists all the alarms which can be generated by an SC300
BTS. Additional Data field values are not shown. The list of alarms is
based on R15 SC300 functionality.
List of Alarms
Table B-1: List of Alarms (Software Release 15)
Alarm
#
Alarm Name Alarm Description
400 Traffic Channel
Element Failure
This trouble notification indicates the availability of a single channel
element or a set of channel elements. It is generated whenever the BTS
detects an alarm condition on a DSP, its internal path connection, or its
associated span. It is never displayed or latched in the MM and it is only
used to update the MMs call processing resource list. This trouble
notification contains the address of the channel card along with the list of
affected channel elements.
1200 BTS LAN Connection
Error
This alarm causes the MM to take the BTS out of service. The MM
converts the alarm ID from 1200 to 1260 (MAWI out of service).
Call Overload Alarms
1950 BTS Overload: New
Calls Threshold 1
Reached
A capacity overload alarm indicates that the new calls capacity ceiling
was reached and mobile restrictions associated with the alarm will be in
effect for the call setups. This alarm is cleared when the overload
condition is no longer in effect. The reporting mechanism is disabled by
default for all overload alarms in this category and can be changed via the
Recent Change command EDIT CARRIER/SECTOR/BTS
CONGESTCONF at the OMCR. Supplemental data represents the state
of the system after the alarm actions have taken place.
1951 BTS Overload: New
Calls Threshold 2
Reached
A capacity overload alarm indicates that the new calls capacity ceiling
was reached and mobile restrictions associated with the alarm will be in
effect for the call setups. This alarm is cleared when the overload
condition is no longer in effect. The reporting mechanism is disabled by
default for all overload alarms in this category and can be changed via the
Recent Change command EDIT CARRIER/SECTOR/BTS
CONGESTCONF at the OMCR. Supplemental data represents the state
of the system after the alarm actions have taken place.
1952 BTS Overload: New
Calls Threshold 3
Reached
A capacity overload alarm indicates that the new calls capacity ceiling
was reached and mobile restrictions associated with the alarm will be in
effect for the call setups. This alarm is cleared when the overload
condition is no longer in effect. The reporting mechanism is disabled by
default for all overload alarms in this category and can be changed via the
Recent Change command EDIT CARRIER/SECTOR/BTS
CONGESTCONF at the OMCR. Supplemental data represents the state
of the system after the alarm actions have taken place.
B