User's Manual
Short Duration Battery Replacement Procedure – continued
DRAFT
SC300 1X BTS Hardware Installation, ATP, and FRU Procedures
JAN 2002
8-18
Table 8-8: Procedure to Remove the Failed Short Duration Battery
Step Action
3 Turn the connector on the short duration battery cable counterclockwise to disconnect the cable
from the unit. See NO TAG. An alarm will be generated.
4 Using a T30 Torx tamper bit remove the two screws that are holding the battery to the unit. See
NO TAG.
Install the replacement battery
Follow the steps in Table 8-8 to install the replacement short duration
battery. Refer to NO TAG.
Table 8-9: Procedure to Install the Replacement Short Duration Battery
Step Action
1 Install the replacement battery according to the “Attaching the Battery to the Unit” installation
procedure in Chapter 5.
2 Re–connect the short–duration battery cable to DC input connector. See Figure 8-5. The alarm
will clear.
3 Re–install the Solar Cover if one is present.
8