User's Manual Part 3

RFDS Setup and Calibration continued
Apr 2001
3-79
SC4812ET BTS Optimization/ATP CDMA LMF
DRAFT
RFDS Calibration
The RFDS Calibration option is used to calibrate the RFDS TX and RX
paths. For a TX antenna path calibration the BTS XCVR is keyed at a
predetermined power level and the BTS power output level is measured
by the RFDS. The power level is then measured at the TX antenna
directional coupler by the power measuring test equipment item being
used (power meter or analyzer). The difference (offset) between the
power level at the RFDS and the power level at the TX antenna
directional coupler is used as the TX RFDS calibration offset value.
For an RX antenna path calibration the RFDS is keyed at a
predetermined power level and the power input level is measured by the
BTS XCVR. A CDMA signal at the same power level measured by the
BTS XCVR is then injected at the RX antenna directional coupler by the
CDMA communications analyzer. The difference (offset) between the
RFDS keyed power level and power level measured at the BTS XCVR is
the RFDS RX calibration offset value.
The TX and RX RFDS calibration offset values are written to the CAL
file.
Prerequisites
BBX2s are is INS_TEST
Cable calibration has been performed
TX calibration has been performed and BLO has bee downloaded for
the BTS
Test equipment has been connected correctly for a TX calibration
Test equipment has been selected and calibrated