User's Manual Part 3
Troubleshooting: Calibration
DRAFT
SC4812ET BTS Optimization/ATP — CDMA LMF
Apr 2001
6-6
Bay Level Offset Calibration
Failure
Table 6-8: Troubleshooting BLO Calibration Failure
Step Action
1 Verify the Power Meter is configured correctly (see the test equipment setup
section) and connection is made to the proper TX port.
2 Verify the parameters in the bts–#.cdf file are set correctly for the following
bands:
For 1900 MHz:
BandClass=1; FreqBand=16
For 800 MHz:
BandClass=0; FreqBand=8
3 Verify that no LPA in the sector is in alarm state (flashing red LED). Reset the
LPA by pulling the circuit breaker, and after 5 seconds, pushing back in.
4 Re-calibrate the Power Meter and verify it is calibrated correctly with cal factors
from sensor head.
5 Verify GPIB adapter is not locked up. Under normal conditions, only 2 green
LEDs must be ‘ON’ (Power and Ready). If any other LED is continuously ‘ON’,
power-cycle (turn power off and on) the GPIB Box and retry.
6 Verify sensor head is functioning properly by checking it with the 1 mW (0 dBm)
Power Ref signal.
7 If communication between the LMF and Power Meter is operational, the Meter
display will show “RES :’’
8 Verify the combiner frequency is the same as the test freq/chan.
6