User's Manual Part 3
Troubleshooting: Download
DRAFT
SC4812ET BTS Optimization/ATP — CDMA LMF
Apr 2001
6-4
Table 6-4: Troubleshooting Code Download Failure
Step Action
1 Verify T1 is disconnected from the BTS at CSU.
2 Verify LMF can communicate with the BTS device using the Status function.
3 Communication to MGLI2 must first be established before trying to talk to any
other BTS device. MGLI2 must be INS_ACT state (green).
4 Verify the card is physically present in the cage and powered-up.
5 If card LED is solid RED, it implies hardware failure. Reset card by re-seating it.
If this persists, replace card from another slot & retry.
NOTE
The card can only be replaced by a card of the same type.
6 Re-seat card and try again.
7 If BBX2 reports a failure message and is OOS_RAM, the code load was OK.
Status it.
8 If the download portion completes and the reset portion fails, reset the device by
selecting the device and reset.
Cannot Download DATA to
Any Device (Card)
Table 6-5: Troubleshooting Data Download Failure
Step Action
1 Re-seat card and repeat code and data load procedure.
2 Verify the ROM and RAM code loads are of the same release by statusing the
card. Refer to Chapter 3, “Download the BTS” for more information.
6