Troubleshooting: Installation
DRAFT
SC4812ET BTS Optimization/ATP — CDMA LMF
Apr 2001
6-2
Cannot Log into Cell-Site
Table 6-1: Login Failure Troubleshooting Procedure
Step Action
1 If MGLI2 LED is solid RED, it implies a hardware failure. Reset MGLI2 by
re-seating it. If this persists, install RGLI2 card in MGLI2 slot and retry. A Red
LED may also indicate no Ethernet termination at top of frame.
2 Verify that T1 is disconnected at the Channel Signaling Unit (CSU). If T1 is still
connected, verify the CBSC has disabled the BTS.
3 Try ‘ping’ing the MGLI2.
4 Verify the LMF is connected to the Primary LMF port (LAN A) in front of the
BTS.
5 Verify the LMF was configured properly.
6 Verify the BTS-LMF cable is RG-58 (flexible black cable of less than 2.5 feet
length).
7 Verify the Ethernet ports are terminated properly.
8 Verify a T-adapter is not used on LMF side port if connected to the BTS front
LMF primary port.
9 Try connecting to the I/O panel (back of frame). Use Tri–Ax to BNC adapter at
the LMF port for this connection.
10 Re-boot the CDMA LMF and retry.
11 Re-seat the MGLI2 and retry.
12 Verify IP addresses are configured properly.
Cannot Communicate to
Power Meter
Table 6-2: Troubleshooting a Power Meter Communication Failure
Step Action
1 Verify Power Meter is connected to LMF with GPIB adapter.
2 Verify cable setup as specified in Chapter 3.
3 Verify the GP–IB address of the Power Meter is set to 13. Refer to Test
Equipment setup section of Chapter 3 for details.
4 Verify that Com1 port is not used by another application.
5 Verify that the communications analyzer is in Talk&Listen, not Control mode.
6